General specifications | |
---|---|
Detection type | magnetic sampling |
Device type | Absolute encoders |
Linearity error | ? ± 0.1 ° |
UL File Number | E223176 "For use in NFPA 79 Applications only" , if UL marking is marked on the product. |
Functional safety related parameters | |
MTTFd | 480 a at 40 °C |
Mission Time (TM) | 20 a |
L10 | 10 E+8 revolutions |
Diagnostic Coverage (DC) | 0 % |
Electrical specifications | |
Operating voltage | 9 ... 30 V DC (with galvanic isolation) |
Power consumption | ? 1.2 W |
Time delay before availability | < 250 ms |
Output code | binary code |
Code course (counting direction) | adjustable |
Interface | |
Interface type | CANopen |
Resolution | |
Transfer rate | min. 20 kBit/s , max. 1 MBit/s |
Cycle time | ? 1 ms |
Standard conformity | DSP 406 |
Connection | |
Connector | M12 connector, 5 pin |
Cable | ?6 mm, 4 x 2 x 0.14 mm2 |
Standard conformity | |
Degree of protection | DINEN60529 , IP68 / IP69K |
Climatic testing | DINEN60068-2-3, no moisture condensation |
Emitted interference | EN61000-6-4:2007 |
Noise immunity | EN61000-6-2:2005 |
Shock resistance | DINEN60068-2-27, 200g, 11ms |
Vibration resistance | DINEN60068-2-6, 30g, 10...1000Hz |
Approvals and certificates | |
UL approval | cULus Listed, General Purpose, Class 2 Power Source , if UL marking is marked on the product. |
Ambient conditions | |
Operating temperature | -40 ... 85 °C (-40 ... 185 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Relative humidity | 98 % , no moisture condensation |
Mechanical specifications | |
Material | |
Mass | approx. 150 g |
Rotational speed | max. 6000 min -1 |
Moment of inertia | 30 gcm2 |
Starting torque | < 5 Ncm |
Shaft load |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |